Stormwater and emergency dewatering are won with two numbers: how much water has to move, and how high it has to go. For this class of work, flow comes first — a pump that moves a lake a few metres is more useful than one that lifts a bucket a hundred metres.
This guide explains how to choose a submersible pump for flood drainage, and where axial-flow, mixed-flow and full tubular (through-flow) designs each fit. Unit note for international readers: 1 m³/h ≈ 4.4 US gpm, and 1 m ≈ 3.28 ft.

Borehole Pumping vs Flood Drainage
| Borehole (deep well) pumping | Flood drainage & dewatering | |
|---|---|---|
| Water source | Groundwater, below the surface | Surface water: rain, river, pond, flooded pit |
| Head (TDH) | Often tens of metres of total dynamic head — note this is not the same as well depth | Usually a few metres of lift plus pipe friction |
| Flow required | Moderate, matched to the well’s safe yield | Large — the faster the water leaves, the less the damage |
| Pump family | Multistage submersible (QJ/QJT) | Axial-flow (QZB), mixed-flow (QHB), full tubular (QGWZ) |
If the water is already at the surface, buy flow, not pressure.
Match the Pump to the Scenario
Municipal stormwater and flood-control stations
For permanent stations, the QGWZ full tubular (through-flow) submersible pump is our flagship. Its wet-stator motor is the key difference: the stator windings are designed to run immersed, and the only mechanical seal in the machine is at the bearing housing. The axial package is roughly half the length of conventional layouts, and the design has been appraised for total pump-station cost savings of over 30%. Where a station must pump in two directions — drainage in the wet season, irrigation in the dry — the QGWZS version uses S-shaped blades and has published forward and reverse performance data for every model.
Irrigation districts and land drainage
The QZB axial-flow and QHB mixed-flow series cover 350–2400 mm outlets, with flow from about 500 m³/h into the tens of thousands m³/h and head of roughly 0.7–22 m across the range. Axial-flow suits the lowest heads with the largest volumes; mixed-flow covers the higher end of low-head work. Blade angles are adjustable (±6° on these series), so a pump can be tuned to the actual duty point. Motors are IP68 with F-class 155 °C insulation and double or triple mechanical seals.
One boundary to state plainly: published model tables cover the common sizes (QGWZ tables run to 1400 mm). Larger diameters are engineered per project — we confirm those parameters with the factory before quoting, rather than promising from a catalogue headline.
Existing sluice and gate retrofits
When a working sluice needs more capacity but no new pump house, the QGWZ/QGWZS gate pump is the answer: the pump flange-mounts directly onto the existing gate and forms the drainage system around it — a “zero-civil-work” arrangement, bolted in place. Documented installations run from 600 to 1000 mm outlets. This is often the fastest way to upgrade aging infrastructure.
Emergency and temporary dewatering
For flood response, construction pits and temporary duty, QZB mobile pump stations on sled or pontoon frames go where no pump house exists. In 2016, eight of these units were allocated by China’s National Flood Control Headquarters for flood-relief work in Hunan, as reported by Hunan TV — the kind of deployment emergency services actually plan around.
Floodwater with debris
Full tubular pumps are built for raw and lightly polluted water, and the manuals put numbers on it: particles up to one tenth of the nominal outlet diameter (a 1600 mm unit passes particles around 160 mm), or solid content up to 2% by volume, depending on the manual edition. For sewage heavy in rags, wet wipes and fibers, hydraulic choice alone is not enough — see our sewage and cutter pump guide.
The Four Numbers You Need to Size One
- Required flow — the volume to remove and the time allowed, or the inflow rate you must keep up with. (For scale: 10,000 m³/h ≈ 44,000 US gpm.)
- Total dynamic head (TDH) — the water-level difference between the flooded side and the discharge side, plus pipe friction. State it as a system figure, not a catalogue headline; our TDH guide explains the calculation.
- Installation form — dry well, gate-mounted, wall-coupled, vertical, inclined, floating or sled-mounted. This often decides the model family before hydraulics does.
- Power supply — voltage, frequency and available capacity. Standard is 380 V / 50 Hz; 660 V is optional; 60 Hz and high-voltage builds are confirmed with the factory per project.
Send those four and we can shortlist a model. A note on tooling: our online pump selector currently covers QJ borehole pumps, so for drainage work the four parameters above are the right route.
Installation and Civil Cost
Submersible axial and tubular pumps eliminate the large pump house that traditional vertical installations require. The manuals describe overall project cost savings of 30–40% for this class of installation, and the full tubular appraisal cites total pump-station cost savings of over 30%. Gate-mounted versions go further on retrofits, because there is no new structure at all.
Reliability Details Buyers Ask About
- Wet stator — patented water-resistant winding wire (ZL 2009 2 0250321.1); windings run immersed, water-cooled directly.
- Adjustable blades — ±6° on QZB/QHB, ±4° on QGWZ, so the duty point can be tuned without replacing the machine.
- Motor protection — IP68 enclosure, F-class 155 °C insulation, double or triple mechanical seals on QZB/QHB.
- Submergence and vortex control — keep the inlet adequately submerged and avoid vortex-prone layouts; a starved inlet is the fastest way to damage a high-flow pump. Dry-run protection and level control are strongly recommended on unattended stations (see how dry-run protection works).
Verification and Credentials
Rather than adjectives, here is what can be checked:
- Testing — national first-class precision test centre, with a PMSCAT grade-1 accuracy accreditation (WTGB202500076, valid 2025–2030). Test capability up to 40 m³/s flow, 3,000 kW power, 1,000 m head and 10 kV. More on our testing and quality inspection.
- Appraisals — full tubular technology appraised by Tianjin authorities in 2015, and a Ministry of Water Resources new-product appraisal in 2016 (No. 12).
- Awards — Dayu water-conservancy science and technology award, second prize (DYJ20150317-D05), for large-scale submersible pump-station technology.
- Certification and systems — water-saving product certification valid to 2028, and ISO 9001 / 14001 / 45001 management systems.
- Reference projects — Nanning Zhupaichong municipal drainage station: ten 1600QGWZ-50-1200 pumps, 1200 kW each at 10 kV, completed 2014; and 24 units for the 2010 Guangzhou Asian Games water-transfer project. See our projects and related field reports on bidirectional tubular pumps, QGWZ factory acceptance testing, and full tubular pump shipments.
- Export history — previous deliveries to the Middle East, Southeast Asia and Europe.

Operating Limits to Respect
QZB/QHB units are rated for raw or lightly polluted water up to 50 °C. QGWZ follows the stricter 2021 instruction manual limit of 40 °C (the older selection manual prints 50 °C). For starting discipline, the 350–900 mm series manual allows up to 10 starts per hour with at least 6 minutes between starts; large high-voltage units follow their project-specific limits. Highly sandy, corrosive or hot water, 60 Hz grids, and high-voltage requirements all need a factory review before we commit to a selection.
FAQ
Can I use a borehole pump for flood drainage?
No — it is the wrong duty. A borehole pump builds high pressure at modest flow; flood drainage needs large flow at low head.
Axial-flow or mixed-flow?
Axial-flow (QZB) for the lowest heads and largest volumes; mixed-flow (QHB) when the required head rises toward the upper end of the low-head range (roughly 10 m and above). The final choice is made against the performance curves.
Can the pump run on a generator?
Usually yes, but sizing matters: starting current depends on the motor and the starting method (direct-on-line, soft start or VFD). Tell us the generator capacity and the pump’s duty point, and we will confirm the combination before quoting.
What size solids can it pass?
For full tubular units, the manuals allow particles up to one tenth of the nominal outlet diameter — about 160 mm on a 1600 mm pump — or up to 2% solids by volume. Hard objects should still be screened out.
Can it pump a pit completely dry?
Submersible pumps need adequate submergence at the inlet and must not run dry. Plan the installation around the minimum water level, and use level control for unattended operation.
What about price and lead time?
Both depend on the model, materials and order scope. Once we have your duty point, we reply with a written quotation stating model, parameters and lead time — see how our factory quotes work.