Water Treatment Equipment &
Supply Systems

Explore Ganquan water treatment equipment and pressure boosting options for community, commercial and industrial water supply. Equipment selection depends on source water quality, required output, treatment targets and delivery pressure.

Tell us where your water comes from and how it will be used. Share any available water analysis, daily demand and existing system details. We can help review suitable treatment and supply equipment and coordinate the technical requirements for your project.

Stainless steel water tank connected by piping to a control cabinet

Built for your source water, not pulled off a shelf. Tell us what is in your water — fluoride, salts, microbes — and we match the treatment process to it.

Applications for Water Treatment & Supply Systems

Community Water Treatment

Treat source water for community supply, with equipment selected according to the raw water analysis, daily demand and required treated water quality.

Commercial & Industrial Treatment

Prepare water for commercial facilities and industrial processes, with treatment options matched to the intended use, required output and specified water quality.

Water Supply Boosting

Boost water pressure for buildings and distribution systems, with equipment matched to the incoming supply pressure, peak demand and required delivery pressure.

Water Treatment & Supply Equipment Options

Ganquan’s catalogue includes water treatment systems, pretreatment equipment and water supply boosting systems. The appropriate equipment combination depends on the source water analysis, required capacity, intended use and site conditions.

SeriesEquipment TypeSelection Focus
GQ-JS(J) / GQ-JS(Z)Water treatment systemsSource water quality, required treated water quality, output and site layout.
ZC-IISand separatorsWater flow, sand particle size and concentration, pressure loss and sand discharge arrangements.
CT-GQIron and manganese removal systemsRaw water analysis, treatment targets, flow and backwash requirements.
Industrial & commercial equipmentWater treatment systems for commercial and process useIntended use, specified water quality, capacity and operating requirements.
GQ-DY(T)Mains-connected booster systemsIncoming supply pressure, peak demand, delivery pressure and local water supply requirements.

Equipment configuration and treatment performance must be reviewed against the actual source water and project requirements. For drinking water applications, the treatment process and verification plan must address the applicable local water quality requirements. Final equipment specifications and supply scope will be confirmed for the proposed system.

Source Water & Project Requirements

Tell us about your water source, intended use and supply requirements. The information below helps us review suitable treatment or boosting equipment and define the scope of your project.

  • Water source: borehole, river, lake, reservoir or mains supply, including any seasonal changes.
  • Water quality: any available raw water analysis and known issues such as sand, turbidity, iron, manganese or salinity.
  • Intended use: community supply, drinking water, commercial facilities or an industrial process.
  • Treatment targets: required treated water quality and any project specifications, if available.
  • Water demand: daily consumption, peak hourly demand and planned operating hours.
  • Supply conditions: incoming water pressure, required delivery pressure and any existing storage tanks.
  • Site conditions: available installation space, power supply and arrangements for backwash or other process wastewater.
  • Operation and maintenance: available operators, access for servicing and local availability of consumables.
  • Existing equipment: current treatment stages, pump details, photographs and the reason for replacement or upgrade.

You can start an inquiry before every detail is known. Share any available water reports, site photographs or system drawings. If a water analysis is not yet available, tell us what you know about the source and intended use so we can identify the information needed for the next stage.

How your RFQ moves

  1. Tell us your source water — analysis if available, people to serve and the supply point
  2. We select the process and size — GQ-JS(J) units with pretreatment, reverse osmosis and UV disinfection, in five sizes from 0.25 to 2.0 m³/h (larger or custom builds confirmed with the factory)
  3. You receive a written quotation with configuration, parameters and lead time
  4. Production and assembly at our Tianjin facility
  5. Every unit is tested before dispatch
  6. Shipment with packing list and documents

You know which step your order is at — no silent weeks.

Ganquan in-house pump test facility with large-diameter test pipeline and water basin
Our in-house test facility — every pump is water-tested before packing
Ganquan pumps packed and ready for shipment to an overseas customer
Pumps leaving our Tianjin facility

Before you compare quotes, check these five lines

  • Source water analysis — fluoride, TDS and microbiology decide the process; a report beats a guess.
  • Daily output vs people served — five sizes from 0.25 to 2.0 m³/h; size to daily demand, not to the village’s name.
  • Process completeness — pretreatment + RO + UV + storage tank. A bare RO skid is not a drinking-water station.
  • Consumables plan — RO membrane life is 3–5 years, filters about 6 months; the overseas supply plan is confirmed with the factory before we promise it.
  • Power, control and lead time — 380 V/50 Hz, automatic or unattended operation with water-level linkage, shortage protection and alarm stop.

A cheaper quote that skips these lines usually costs more later.

Frequently Asked Questions

Our area has high-fluoride water. Can this equipment remove fluoride?
That is exactly what the GQ-JS(J) line is built for — rural high-fluoride and brackish water, with RO as the main defluoridation step. Send us your water report and we will confirm the inlet limits and expected output quality with the factory.

Can it run unattended in a village with no operator?
Yes — automatic operation with water-level linkage, water-shortage protection, and alarm-and-stop when readings go out of limits.

What happens when membranes and filters run out?
RO membranes last 3–5 years and filters about 6 months. The overseas consumables supply plan is confirmed with the factory before we make any promise on it.

Tell Us About Your Water Treatment or Supply Project

Tell us your project location, water source and intended use. Include any known daily demand, water quality targets or supply pressure requirements. We can help review suitable treatment or boosting equipment and clarify the information needed for a quotation.

Start with the information you have. Water analysis reports, photographs of the existing system and site drawings can help us understand your needs. If a technical detail is unknown, simply tell us.

Scroll to Top